How does floor heating have the longest service life

Author: admin / 2020-06-17

Adjust the temperature of the ground and water pipes

When the geothermal heating system is activated for the first time, the temperature must be raised strictly according to the heating program. The operation method is as follows:

Pour 40°C-50°C water into the pipes inside the main water supply valve and the main return valve, and then observe whether the floor heating temperature is between 18°C ​​and 22°C, and whether the temperature of the water pipe is 45° About C, because the floor heating system needs to be within a fixed temperature range, not, the higher the temperature, the better.

Therefore, it is recommended that everyone must observe the temperature, so as not to shorten the service life of the floor heating due to the discomfort of temperature adjustment.

Temperature adjustment should be gradual

Whether it is water floor heating or electric floor heating, any floor or tile has the defect of expansion and deformation when exposed to heat. Therefore, before turning on the floor heating system, you should turn on the various circuits of the floor heating, turn on the thermostats of each room and heating area, and then gradually heat up.

For example, the temperature rises slowly in the first three days: 12°C on the first day, 16°C on the second day, 20°C on the third day, and the temperature can be raised to normal on the fourth day.

It should be noted here: the water temperature should not exceed 45℃, and the water temperature setting is too high, which not only affects the comfort, but may also affect the service life of the floor.

By the same token, when the weather is warm, the indoor temperature should not be cooled too fast, and the floor heating system should be turned off gradually. If the temperature drops suddenly, the service life of the floor will also be shortened.

Check if there is any leakage of water or electricity when suppressing

The floor heating system is a closed loop system. After a long time of heating, cooling or standing still, it will cause water to evaporate, resulting in a decrease in the amount of water in the pipeline, resulting in a drop in system pressure.

Therefore, when we run the floor heating system for the first time, we need professionals to perform pressure test on the pipeline system, make the system water and pressurize, so that the system pressure can be restored to the normal value, and to ensure the normal operation of the system.

Secondly, in the process of replenishing water, you need to open the exhaust equipment to remove the air from the system at the same time. At the same time, observe whether there is water leakage during the suppression process. If there are no problems, it can be used normally.

Finally, I would like to remind everyone: In addition to checking whether the filters, valves, thermometers, pressure gauges, etc. can be used normally before the floor heating system is running, during the winter heating period, we must also ask some professionals to set the front-end valves and valves of the floor heating system. The manifold is checked for tightening, and the impurities in the filter are cleaned regularly.

If it is damaged, it must be inspected and repaired before use.

In addition, if you want to maintain the efficient operation of the floor heating system, a professional HVAC company should regularly clean and maintain the floor heating pipelines and equipment.



×